BeGraft
Improving your performance. The world‘s first peripheral Stent Graft System made of Cobalt-Chromium (CoCr) with an ePTFE covering that delivers a reliable solution for challenging arterial anatomies in complex endovascular procedures.

Learn more

6 F compatibility up to Ø 8 x 57 mm
for reliable lesion care in complex cases
to meet a wider choice of patient requirements including Iliacs, Renals, and FEVAR. *For full information, please see Instructions for Use
Indication
The BeGraft is indicated for permanent intraluminal placement in iliac and renal arteries for
restoring and improving the patency impaired by arteriosclerosis or other stenoses that may be treated by stenting
sealing aneurysms, acute perforations, acute ruptures and fistulas
Furthermore, the BeGraft is indicated for use as a bridging stent graft in patients requiring endovascular abdominal aortic aneurysm repair with a fenestrated aortic endovascular graft to keep the visceral arteries perfused.
For full information, please see Instructions for Use.
Technical specifications
Catheter
PTA catheter
0.035" OTW
Catheter lengths
75 & 120 cm
Introducer sheath compatibility
up to ø 8 mm | 6 F |
ø 9 mm and 10 mm | 7 F |
Stent
Open-cell design
CoCr (L-605)
Stent lengths
18 - 58 mm
ePTFE cover
Patented ePTFE cover fixation at both stent ends
Three different stent designs:
At nominal pressure: | |
Small Vessel design (SV) | ø 5 - 6 mm |
Medium Vessel design (MV) | ø 7 - 8 mm |
Large Vessel design (LV) | ø 9 - 10 mm |
Shelf life
3 years
Ordering information
Nominal Stent Graft Length | Introducer Sheath Size | Catalogue Number for Catheter Length | |
|---|---|---|---|
75 cm | 120 cm | ||
Expanded Stent Graft Diameter | Nominal Stent Graft Length | Introducer Sheath Size | Catalogue Number for Catheter Length | |
|---|---|---|---|---|
75 cm | 120 cm | |||
5 mm | 18 mm | 6 F | BGP1805_1 | BGP1805_2 |
22 mm * | BGP2205_1 | BGP2205_2 | ||
28 mm * | BGP2805_1 | BGP2805_2 | ||
38 mm * | BGP3805_1 | BGP3805_2 | ||
58 mm | BGP5805_1 | BGP5805_2 | ||
6 mm | 18 mm | 6 F | BGP1806_1 | BGP1806_2 |
22 mm * | BGP2206_1 | BGP2206_2 | ||
28 mm * | BGP2806_1 | BGP2806_2 | ||
38 mm * | BGP3806_1 | BGP3806_2 | ||
58 mm | BGP5806_1 | BGP5806_2 | ||
7 mm | 18 mm | 6 F | BGP1807_1 | BGP1807_2 |
23 mm * | BGP2307_1 | BGP2307_2 | ||
27 mm * | BGP2707_1 | BGP2707_2 | ||
37 mm * | BGP3707_1 | BGP3707_2 | ||
57 mm | BGP5707_1 | BGP5707_2 | ||
8 mm | 27 mm * | 6 F | BGP2708_1 | BGP2708_2 |
37 mm * | BGP3708_1 | BGP3707_2 | ||
57 mm | BGP5708_1 | BGP5707_2 | ||
9 mm | 27 mm * | 7 F | BGP2709_1 | BGP2709_2 |
37 mm * | BGP3709_1 | BGP3709_2 | ||
57 mm | BGP5709_1 | BGP5709_2 | ||
10 mm | 27 mm * | 7 F | BGP2710_1 | BGP2710_2 |
37 mm * | BGP3710_1 | BGP3710_2 | ||
57 mm | BGP5710_1 | BGP5710_2 | ||
*Sizes indicated for FEVAR indication only | ||||